Hinged Freezer Door 012

Attention: open in a new window. PrintE-mail

Tiefkühlraumdrehtüre Typ 012

Leaf:

Sandwich structure, leaf thickness 120 mm, semi-supported. The metal sheath is filled under pressure (48 kg/m³) with PUR foam. Energy saving low temperature interrupter and easy-to-replace gasket with hollow chamber seal. 230V~ heating cable in sealing area.
Door leaf heating in the area of the central partition.

Fixed frame:

Full metal construction PUR foamed with low temperature interrupter. Visible surfaces are, like the door leaf, metal clad.
Replaceable circulating frame heating under a cover profile (230V~).
Plastic threshold, 70 mm high.

Fittings:

Safety press lock with integrated emergency release, outside handle with profile cylinder, inside handle emergency green with instruction.
Three-dimensionally adjustable rising edge hinges, black.
Door leaf can be taken off its hinges.

Options:

  • Clamping frame for different panel thicknesses
  • Flat frame (in various dimensions)
  • Block frame (in various dimensions)
  • Special frames on request
  • heated pressure balancing element
  • Inverse lock function for inwards opening doors
  • Various door fittings (e.g. "Optional" or "Euro 2000")
  • Various door hinges (e.g. Type "FUTURO" or "VARIOFLEX")
  • Multiple-point locks (e.g. two or three-point lock)
  • Touch-free contact switch (inductive) or mechanical
  • Door leaf thickness 140 mm
  • Door leaf thickness 160 mm
  • Various protection systems (e.g. plastic or stainless steel)
  • Integrated insulated glass window (heated or unheated) in various designs
  • Electric operator for hinged doors